U S E R M A N U A L
AIR-OXYGEN BLENDER
(DISS and NIST Connections)
Model No. PM5200 Series
PM5300 Series (shown)
SAVE THESE INSTRUCTIONS
CAUTION
Federal (USA) law restricts this device to sale
by or on the order of a physician.
300 Held Drive Tel: (+001) 610-262-6090
Northampton, PA 18067 USA Fax: (+001) 610-262-6080
www.precisionmedical.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - U S E R M A N U A L

U S E R M A N U A LAIR-OXYGEN BLENDER(DISS and NIST Connections)Model No. PM5200 SeriesPM5300 Series (shown)SAVE THESE INSTRUCTIONSCAUTIONFederal (U

Strona 2 - CONTENTS

9BlenderAir-OxygenCOMPONENT DESCRIPTIONITEM DESCRIPTIONF Air Inlet Fitting A male DISS or NIST air fitting with one way valve that is used to connect a

Strona 3 - EXPLANATION OF ABBREVIATIONS

10BlenderAir-OxygenALARM TEST1. The Air-Oxygen Blender is installed and the flowmeter is turned on. Disconnect or turn off the air supply line to the A

Strona 4 - Air-Oxygen

11BlenderAir-Oxygen3. To activate the bleed, turn the knurled collar until the bleed pin is engaged. Then slide the collar back until it contacts the

Strona 5

12BlenderAir-Oxygen1. Disconnect all gas connections and equipment before cleaning. 2. Clean exterior surfaces with a cloth dampened with mild deterge

Strona 6 - SPECIFICATIONS

13BlenderAir-OxygenTROUBLESHOOTINGIf the Air-Oxygen Blender fails to function, consult the Troubleshooting Guide below.If problem cannot be solved

Strona 7 - Pressure Drop:

14BlenderAir-OxygenLIMITED WARRANTY AND LIMITATION OF LIABILITYPrecision Medical, Inc. warrants that the Blender, (the Product), will be free of defec

Strona 8 - DIAGRAMS

DECLARATION OF CONFORMITYManufacturer: Precision Medical, Inc.300 Held Drive, Northampton, PA 18067, USA CONTACT: Quality Manager Phone: 610-262-6090

Strona 9

1BlenderAir-OxygenCONTENTS RECEIVING / INSPECTION ...2INTENDED USE ...

Strona 10 - INSTALLATION

2BlenderAir-OxygenRECEIVING / INSPECTIONRemove the Precision Medical, Inc. Air-Oxygen Blender from the packaging and inspect for damage. If there is a

Strona 11 - OPERATING INSTRUCTIONS

3BlenderAir-OxygenSAFETY INFORMATION - WARNINGS AND CAUTIONS DANGERIndicates an imminently hazardous situation which, if not avoided, will re

Strona 12 - CLEANING

4BlenderAir-OxygenWARNINGAn Oxygen Analyzer/Monitor must be used to verify oxygen concentration.Accuracy of oxygen concentration will be affected if b

Strona 13 - DISPOSAL INSTRUCTIONS

5BlenderAir-OxygenSPECIFICATIONS Model PM5200 High Flow PM5300 Low FlowPrimary OutletFlow Range15 - 120 lpm 3 - 30 lpmWith both supply pressures at 50

Strona 14 - TROUBLESHOOTING

6BlenderAir-OxygenSPECIFICATIONS continuedDimensions: (without fittings) Depth: 4.9 in (12.5 cm) Width: 2.3 in (5.7 cm) Height: 4.1 in (10.

Strona 15 - LIMITATION OF LIABILITY

7BlenderAir-OxygenDIAGRAMSCAUTIONMissing or illegible labels must be replaced, contact Precision Medical, Inc.Depending on model, your fittings may dif

Strona 16 - DECLARATION OF CONFORMITY

8BlenderAir-OxygenCOMPONENT DESCRIPTIONITEM DESCRIPTIONA Oxygen Concentration Dial A dial used for selecting oxygen concentrations between 21%-100%.

Powiązane modele: PM5300

Komentarze do niniejszej Instrukcji

Brak uwag